Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 3 Years |
Still deciding? Get samples of US$ 1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product:Grooved Reducing Tee with Thread
Code:XGQT04S
Size: 2''*1''-8''*3''(DN50x25-DN200x80)
Material: Ductile iron ASTM A536, 65-45-12
Dimension: ISO6182,AWWA C606,GB 5135.11
Connection:ASME B36.10,ASTM A53-A53M,ISO 4200
Thread: If have ISO 7-1,BS 21,BSPT, NPT,ASME B1.20.1
Pressure Rating: 175PSI-500PSI
Surface Treatment: Red Painting,Epoxy Coating ,Hot-Dip Galvanized,Electroplated
Bolt & nut: ASTM A449/ CLASS 8.8/ ISO 898
Gasket: EPDM, Nitrile, Silicone rubber, etc.
Certificate: UL Listed / FM Approved
Application: Fire Protection,Waterworks,HVAC,Plumbing,GAS,Irrigation,or other piping systems
Threaded grooved reducing tees are pipe fittings that combine threaded and grooved connections. This type of tee allows for versatility in connecting pipes within a duct system. Threaded connections involve the use of threads on pipes and fittings, twisting them together to form a strong joint. Grooved connections, on the other hand, typically involve grooves on the pipe ends along with a gasket and coupling system to create a sealed connection.
Connection standards for threaded connections are typically governed by standards such as the American National Standards Institute (ANSI) or the International Organization for Standardization (ISO), depending on the region and application. For example, ANSI/ASME B1.20.1 is the pipe thread standard, and ISO 7-1 is the international standard for pipe threads.
For grooved connections, as mentioned in a previous reply, standards such as ANSI/NFPA 53 and ISO 6182 are often cited, but the specific standards may vary by industry and region.
It is important to note that the combined use of threaded and grooved connections may be affected by the specific requirements of the piping system, the type of fluid being conveyed, and applicable codes and regulations at a given location. Always refer to the manufacturer's guidelines and relevant industry standards to ensure proper installation and compatibility in your specific application.
Nominal Size mm/in |
Pipe O.D mm |
Working Pressure PSI/Mpa |
Dimensions mm/in |
Certificate | |
∅ | L | ||||
50X25/2X1 | 60.3X33.7 | 300/2.07 | 70/2.57 | 70/2.57 | FM UL |
50X32/2X114 | 60.3X42.4 | 300/2.07 | 70/2.57 | 70/2.57 | FM UL |
50X40/2X1Y2 | 60.3X48.3 | 300/2.07 | 70/2.57 | 70/2.57 | FM UL |
65X32/212X114 | 73.0X42.4 | 300/2.07 | 76/3.00 | 76/3.00 | FM UL |
65X40/2V2X1Y2 | 73.0X48.3 | 300/2.07 | 76/3.00 | 76/3.00 | FM UL |
65X50/212X2 | 73.0X60.3 | 300/2.07 | 76/3.00 | 76/3.00 | FM UL |
65X25/30DX1 | 76.1X33.7 | 300/2.07 | 76/3.00 | 76/3.00 | FM UL |
65X40/30DX112 | 76.1X48.3 | 300/2.07 | 76/3.00 | 76/3.00 | FM UL |
65X50/30DX2 | 76.1X60.3 | 300/2.07 | 76/3.00 | 76/3.00 | FM UL |
80X25/3X1 | 88.9X33.7 | 300/2.07 | 86/3.38 | 86/3.38 | FMUL |
80X32/3X114 | 88.9X42.4 | 300/2.07 | 86/3.38 | 86/3.38 | FM UL |
80X40/3X1Y2 | 88.9X48.3 | 300/2.07 | 86/3.38 | 86/3.38 | FM UL |
80X50/3X2 | 88.9X60.3 | 300/2.07 | 86/3.38 | 86/3.38 | FM UL |
80X65/3X3OD | 88.9X76.1 | 300/2.07 | 86/3.38 | 86/3.38 | FM UL |
100X65/414ODX3OD | 108.0X76.1 | 300/2.07 | 102/4.01 | 102/4.01 | FM UL |
100X80/414ODX3 | 108.0X88.9 | 300/2.07 | 102/4.01 | 102/4.01 | FM UL |
100X25/4X1 | 114.3X33.7 | 300/2.07 | 102/4.01 | 102/4.01 | FM UL |
100X32/4X114 | 114.3X42.4 | 300/2.07 | 102/4.01 | 102/4.01 | FM UL |
100X40/4X1V2 | 114.3X48.3 | 300/2.07 | 102/4.01 | 102/4.01 | FM UL |
100X50/4X2 | 114.3X60.3 | 300/2.07 | 102/4.01 | 102/4.01 | FMUL |
100X65/4X212 | 114.3X73.0 | 300/2.07 | 102/4.01 | 102/4.01 | FM UL |
100X65/4X30D | 114.3X76.1 | 300/2.07 | 102/4.01 | 102/4.01 | FM UL |
100X80/4X3 | 114.3X88.9 | 300/2.07 | 102/4.01 | 102/4.01 | FMUL |
125X25/5120DX1 | 139.7X33.7 | 300/2.07 | 124/4.88 | 124/4.88 | FM UL |
125X32/512ODX1V4 | 139.7X42.4 | 300/2.07 | 124/4.88 | 124/4.88 | FM UL |
125X40/512ODX1V2 | 139.7X48.3 | 300/2.07 | 124/4.88 | 124/4.88 | FM UL |
125X50/5120DX2 | 139.7X60.3 | 300/2.07 | 124/4.88 | 124/4.88 | FMUL |
125X65/512ODX212 | 139.7X76.1 | 300/2.07 | 124/4.88 | 124/4.88 | FM UL |
125X80/512ODX3 | 139.7X88.9 | 300/2.07 | 124/4.88 | 124/4.88 | FM UL |
150X65/614ODX3OD | 159.0X76.1 | 300/2.07 | 140/5.50 | 140/5.50 | FM UL |
150X80/614ODX3 | 159.0X88.9 | 300/2.07 | 140/5.50 | 140/5.50 | FM UL |
150X25/612ODX1 | 165.1X33.7 | 300/2.07 | 140/5.50 | 140/5.50 | FM UL |
150X32/612ODX114 | 165.1X42.4 | 300/2.07 | 140/5.50 | 140/5.50 | FM UL |
150X40/6V2ODX12 | 165.1X48.3 | 300/2.07 | 140/5.50 | 140/5.50 | FM UL |
150X50/612ODX2 | 165.1X60.3 | 300/2.07 | 140/5.50 | 140/5.50 | FM UL |
150X65/612ODX3OD | 165.1X76.1 | 300/2.07 | 140/5.50 | 140/5.50 | FM UL |
150X80/6V2ODX3OD | 165.1X88.9 | 300/2.07 | 140/5.50 | 140/5.50 | FM UL |
150X25/6X1 | 168.3X33.7 | 300/2.07 | 140/5.50 | 140/5.50 | FM UL |
150X32/6X114 | 168.3X42.4 | 300/2.07 | 140/5.50 | 140/5.50 | FM UL |
150X50/6X2 | 168.3X60.3 | 300/2.07 | 140/5.50 | 140/5.50 | FM UL |
150X65/6X212 | 168.3X73.0 | 300/2.07 | 140/5.50 | 140/5.50 | FM UL |
150X80/6X3 | 168.3X88.9 | 300/2.07 | 140/5.50 | 140/5.50 | FM UL |
200X65/8X3OD | 219.1X76.1 | 300/2.07 | 175/6.89 | 175/6.89 | FM UL |
200X80/8X3 | 219.1X88.9 | 300/2.07 | 175/6.89 | 175/6.89 | FM UL |
Products are used in fire protection system, water system, HVAC system, plumbing, gas system, irrigation system, etc.These products are used in many projects , such as China Taiwanese Building 101, Xiamen Building,Wuhan Expo Building and other famous landmark projects.