Fire Fighting Pipes FM UL Listed Fire Protection System Fire Sprinkler System Stainless Steel Flexible Hose

Product Details
Customization: Available
Sprinkler Installation: Sidewall/Upright/Pendent
Sprinkler Head Type: Open
Still deciding? Get samples of US$ 0/Piece
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
2 languages freely used by foreign trade staff. include: English, Spanish
Fast Delivery
The supplier can deliver the goods within 30 days
Low MOQ
The MOQ for the supplier's products is 1
to see all verified strength labels (12)
  • Fire Fighting Pipes FM UL Listed Fire Protection System Fire Sprinkler System Stainless Steel Flexible Hose
  • Fire Fighting Pipes FM UL Listed Fire Protection System Fire Sprinkler System Stainless Steel Flexible Hose
  • Fire Fighting Pipes FM UL Listed Fire Protection System Fire Sprinkler System Stainless Steel Flexible Hose
  • Fire Fighting Pipes FM UL Listed Fire Protection System Fire Sprinkler System Stainless Steel Flexible Hose
  • Fire Fighting Pipes FM UL Listed Fire Protection System Fire Sprinkler System Stainless Steel Flexible Hose
  • Fire Fighting Pipes FM UL Listed Fire Protection System Fire Sprinkler System Stainless Steel Flexible Hose
Find Similar Products
  • Overview
  • Factory tour
  • Detailed Photos
  • Different types
  • accessories
  • Our Advantages
  • Installation
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Automatically Opened and Closed Repeatedly
Can Automatically Opened and Closed
Open Fire Sprinkler System Type
Water Spray System
Closed Fire Sprinkler System
Wet Fire Sprinkler System
Dry Alarm Valve Type
Differential Type
Wet Alarm Valve Structure
Butterfly Valve Type
Alarm Valve Diameter
80mm
Nozzle Flow Coefficient
115
Deluge Valve Type
Thermal Type
Brand
Realflex
Thread
BSPT/NPT
Stainless Steel
304 304L 316 316L
Certificate
FM/UL/Nfpa
Model
Braided/Unbraided
Length
28" 40" 48" 60" 72"
L
700mm,1000mm,1200mm,1500mm,1800mm
Inlet
1",1-1/4"
Outlet
3/8"-1"(DN10-DN25)
MOQ
1 PCS
Lead Time
10-30 Days
Related Products
CS Nipples/Gi Fittings/Flanges/Valves
Max. Pressure
203 Psi/14 Bars/1.4MPa
Packaging Details
Cartons, Pallets
Max. Temp.
66 Celsius/ 150 Fahrenheit
Transport Package
Cartons
Specification
1/2", 3/4"
Trademark
Realflex
Origin
Zhejiang
HS Code
8424899990
Production Capacity
100000PCS/Week

Product Description


Fire Fighting Pipes FM UL Listed Fire Protection System Fire Sprinkler System Stainless Steel Flexible Hose
Factory tour

Fluid Tech Group is a professional manufacturer of pipe fittings in China. All products are designed, manufactured and tested in strict accordance with DIN, BS, ISO, ANSI, API and JIS standards.
We focus on the fire protection system for more than 10 years. Until now, we can offer one-stop service to our client who are specialized in fire protection system. Our products include the GI fittings, BMI fittings, Grooved fittings, fire valves, flexible hose, sprinkler, pipe hangers and so on. All items are FM approved and UL listed which are required in fire protection system. 
At present, our products are exported to North America, Europe, Central and South America, Southeast Asia, Middle East and Africa markets, and the products are very popular.


Fire Fighting Pipes FM UL Listed Fire Protection System Fire Sprinkler System Stainless Steel Flexible Hose
Detailed Photos
Fire Fighting Pipes FM UL Listed Fire Protection System Fire Sprinkler System Stainless Steel Flexible Hose
Refer No. Description Material No. of each set
1 Corrugated tube braid&collar-rings SS 304 1
2 Discharge nipple(elbow) Galv.Steel ASTM 1020 1
3 Inlet nipple Galv.Steel ASTM 1020 1
4 Hexagon slip nut Galv.Steel ASTM 1020 2
5 Gasket EPDM 2
6 Isolation ring Nylon 66 2
7 Center bracket Galv.Steel 1
8 Side bracket Galv.Steel 2
9 Square bar Galv.Steel 1
10 Bolt&screws Galv.Steel 1 set
Different types

Fire Fighting Pipes FM UL Listed Fire Protection System Fire Sprinkler System Stainless Steel Flexible Hose

Flexible hose         cULus listing data
Model Sprinkler thread size Max.allow Sprinkler 
K-factor
Max. no. of  90° bends Min.bending radius EQL of 33.7mm/1" SCH40 Pipe
DN(in.) Metric/Imprl. n x 90° mm /inch meters /feet
RF-100-700 15(1/2") 80/5.6 2 100 8.2/27.0
20(3/4") 202/14.0 3.9 8.5/28.0
RF-100-1000 15(1/2") 80/5.6 3 100 11.3/37.0
20(3/4") 202/14.0 3.9 12.5/41.0
RF-100-1200 15(1/2") 80/5.6 3 100 14.9/49.0
20(3/4") 202/14.0 3.9 14.3/47.0
RF-100-1500 15(1/2") 80/5.6 3 100 19.2/63.0
20(3/4") 202/14.0 3.9 19.5/64.0
RF-100-1800 15(1/2") 80/5.6 4 100 23.8/78.0
20(3/4") 202/14.0 3.9 24.4/80.0

Fire Fighting Pipes FM UL Listed Fire Protection System Fire Sprinkler System Stainless Steel Flexible Hose

Flexible hose         cULus listing data
Model Sprinkler thread size Max.allow Sprinkler 
K-factor
Max. no. of  90° bends Min.bending radius EQL of 33.7mm/1" SCH40 Pipe
DN(in.) Metric/Imprl. n x 90° mm /inch meters /feet
RF-200-700 15(1/2") 115/8.0 1 250 8.1/26.7
20(3/4") 202/14.0 9.8 6.5/21.5
RF-200-1000 15(1/2") 115/8.0 2 250 12.9/42.6
20(3/4") 202/14.0 9.8 12.0/39.6
RF-200-1200 15(1/2") 115/8.0 3 250 16.2/53.2
20(3/4") 202/14.0 9.8 15.7/51.6
RF-200-1500 15(1/2") 115/8.0 4 250 20.6/67.8
20(3/4") 202/14.0 9.8 19.3/63.5
RF-200-1800 15(1/2") 115/8.0 4 250 25.1/82.4
20(3/4") 202/14.0 9.8 22.9/75.4

Fire Fighting Pipes FM UL Listed Fire Protection System Fire Sprinkler System Stainless Steel Flexible Hose
Stainless Unbraided Hose with Straight Nipple(Unbraided flexible sprinklers hose & fittings) assembly consists of an unbraided corrugated hose, inlet steel fitting to connect the branch line, outlet fitting to connect the sprinklers, and bracket assembly to mount on the ceiling.The fire hose is composed of stainless steel bellows hose, joint fittings and fixed bracket groups, which provides an innovative simple and efficient installation method for the end sprinkler of the fire sprinkler system, replacing the traditional installation method of short pipe sleeve + steel parts.
 

accessories
Fire Fighting Pipes FM UL Listed Fire Protection System Fire Sprinkler System Stainless Steel Flexible Hose
Fire Fighting Pipes FM UL Listed Fire Protection System Fire Sprinkler System Stainless Steel Flexible Hose
Our Advantages

Safe & Reliable
All the parts fexible hoses are manufactured in corrosion resistant and high-powered stainless steel with 100% leak tested prior to leaving the factory and the environmental temperature resistance being as high as 107ºC/225ºF
Easy and Quick installation 
No special tools are required and It only needs the simple use of wrench, screw driver and pipe sealing tape, etc, in the installation with the minimal amount of time. The fexibility hose can be adjusted based on the installation space and can also be combined with 90' elbow, which allows hose to be fxed in limited installation space.
Economizing on cost With the unique connection mode of fexible hose, the MECH brand is much more time and cost saving and with no need of any machine against traditional hard pipe system installation.
Environmental Friendly
The flexible hose can be re-shaped and relocated to suit the final sprinkler location on the ceiling without draining the system, avoiding the pipe wasted by the inaccurate measurement. No sprinkler displacement even after high pressure test and eliminating the need for an oversized ring around the sprinkler.
Seismically
The stainless steel hose can absorb seismic shock, and protect the sprinkler system to maintain normal operation in the case of an earthquake.
Installation
Fire Fighting Pipes FM UL Listed Fire Protection System Fire Sprinkler System Stainless Steel Flexible Hose
A.Connect Inlet Nipple
Use pipe wrench to screw the Inlet Nipple into the branch outlet interface on water supply pipeline,use pipe sealant (tape or pipe glue etc.) to seal and apply tightening torque of approx.50N·m/35ft-lbs.Then tighten the Hexagon Slip Nut with 28N·m/20ft-lbs to ensure sealing performance.
B. Fix bracket set
Attach side brackets to the main-rail of the T-bar grid and cross the square bar through 2 side brackets,with the center bracket in the middle.Tighten all fixing bolt on the side brackets with 4N·m/3ff-lbs.
C. Bending &Locating
Bend the Flexible Hose body as desired (according to Technical Specification of each style of flexible hoses) and locate the Discharge Nipple into the center bracket.Tighten the bolts on center bracket with 4N·m/3ft-lbs after the proper location of sprinkler head has been found.
D. Connect Discharge Nipple
Tighten the Slip Nuts with 28N·m/20ft-lbs and install sprinkler head to Discharge Nipple by following the sprinkler manufacture's installation instructions. Finally test leak in according with NFPA guidelines.

 

Fire Fighting Pipes FM UL Listed Fire Protection System Fire Sprinkler System Stainless Steel Flexible Hose

 

Packaging & Shipping
Fire Fighting Pipes FM UL Listed Fire Protection System Fire Sprinkler System Stainless Steel Flexible Hose
FAQ

1. What is the minimum quantity of the order? 
Answer: No MOQ requirement

2. How long is the delivery time of the order?
Answer: The delivery time for general orders is about 15 days. If the order is urgent and we have stock, around 7 days.

3. What payment methods do you accept?
Answer: We accept payment terms such as TT, L/C, DP, Western Union, Paypal, etc.

4. Where is your departure port of shipment? Is it possible to deliver to the designated warehouse?
Answer: The port of departure of our goods is generally Tianjin Port or Qingdao Port. We can transport the goods to designated warehouses, such as Yiwu, Guangzhou, etc.

5. What certificates do your products have?
Answer: Our products have FM/UL certificates, and we cooperate with third-party quality inspection certification before the factory, such as SGS,TUV

6.What are the series of your products?
Answer: Our products are divided into heavy series, medium series and light series according to different markets and standards. In order to buy more competitive products for you, please communicate your purchasing needs with the salesperson.

7. Do product packaging cartons and labels support customization?
Answer: Packaging cartons and labels can be customized according to customer requirements.

8.Does the purchased product support customization?
Answer: The product supports customization, but there are purchase quantity requirements and mold costs. For details, please consult the salesperson.

9.What are the packaging methods of the product?
Answer: The packaging of the product includes carton packaging, pallet packaging, wooden box packaging, and woven bag packaging.
Fire Fighting Pipes FM UL Listed Fire Protection System Fire Sprinkler System Stainless Steel Flexible Hose

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier